The maximum deflection of the top rail when a load. Minimal components, user-friendly design, and self-contained kits all combine for simplicity and ease of use. The single guard rail columns are 17″ high. Combine with SafePro weighted guardrail base plates (57-lb) for a simple, secure installation. 0 ˜ . 1910. Where workers on a construction site are exposed to vertical drops of 6 feet or more, OSHA requires that employers provide fall protection in one of three ways before work begins: Placing guardrails around the hazard area. 500 1926. •Guardrail systems •Safety net systems •Personal Fall Arrest Systems •Positioning systems •Travel Restraint systems •Ladder Safety systems. 1 m) plus or minus 3 inches (8 cm) above the walking/working level. OSHA also states that the guardrails must be between 39 and 45 inches tall. 502(b), including the top rail height requirement in §1926. HSS offers a wide variety of guardrail and guardrail systems. In particular, toeboards used for falling object protection are as follows: Toe Board Height Requirements: 29 (k) (1) (ii): “have a vertical minimum height of 3. 28 (b) (1) (i) The top rail is smooth surfaced and is 42-inches nominal height and the railing system has the strength to withstand at least 200 pounds of applied top rail pressure. 501(b)(2), 1926. The following definitions apply in this subpart: Alternating tread-type stair means a type of stairway consisting of a series of treads that usually are attached to a center support in an alternating manner such that an employee typically does not have both feet on the same level while using the stairway. The only exception is for 1926. 1926. 4741 or 832. You’re completely OSHA compliant for inspection at a moments notice. However, OSHA 1910. See WAC 296-880-40010 for other specific criteria for ramps, runways, and inclined walkways. OSHA compliant instructions attached to each section. 25 (b) (2) Vertical clearance above any stair tread to any overhead obstruction is at least 6 feet, 8 inches (203 cm), as measured from the leading edge of the tread. Rail - galvanized 406930G 8. Factory Supply supplies, builds, designs and custom engineers OSHA and ANSI compliant rooftop guardrail systems for fall protection. ladders on a slippery surface must be. In response to your request for other interpretations relevant to 1926. 23 includes requirements for ladders, where OSHA defines handrail requirements on platforms and how high safety railings must be. 6300 W by NW Blvd #100, Houston, TX 77040 (800) 962-6111Lighthouse Safety’s permanent free-standing roof guardrail is recognized for its superior quality by companies all over the world. For the purposes of this post, we are not considering the construction industry safety monitor system. A barrier erected to prevent employees from falling to lower levels. Handrail refers to a graspable element of a railing system designed to assist you in ascending or descending a staircase. in any direction per OSHA 1910. The freestanding design is non-penetrating, so there’s no danger of roof leaks. Must Withstand 200 Pounds. hot rolled pickled electric weld tubing, free of sharp edges and snag points. 1910. Rail - galvanized 404656G 5. 8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems. 23, 1991]. (1067 mm ±76 mm) high, with a mid-rail 21 in. The specific provision depends on the work activity and the type of hazard. Fully Tested & Exceeds Current Safety Requirements. 29 (b) (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. 29 (b) (3) (4) (5). , or. 28 defines toe board requirements for “employers to provide protection for each employee exposed to fall and falling object hazards. It means OSHA standards have been met or exceeded so your workers can focus on the job at hand. 501(b)(2), 1926. Handrails and the top rails of stair rail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in. Find out which FIXFAST USA guardrail system is best for you. 593. Whether in construction or general industry, a structural engineer may be called upon to design a new guardrail system or to evaluate the adequacy of an existing guardrail system in accordance with the Codes of the local jurisdiction. The OSHA standard for guardrail height is 42 inches. OSHA 29 CFR 1910. 500(a)(2) or in § 1926. 29 Fall Protection Systems and Falling Object Protection-Criteria and Practices > 1910. Currently, our position is that the safety railing system required in . (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. 1926. Section 1926. So, workers are using 30 inch stilts, the guardrail needs to be 72 inches tall (42 inches plus 30 inches). for LORGUARD™. 28 and 1910. 6 centimeters) nominal diameter or thickness to prevent cuts and lacerations. OSHA notes that easily attachable guardrail systems which overcome any such problem are commercially available. In stock and ready to ship. Bolted diagonal bridging means diagonal bridging that is bolted to a steel joist or joists. Guardian G-Rail Safety Railing System. If you are going to take the time to build a faulty guardrail system, you might as well take the. IMPORTANCE OF SAFETY RAILING SYSTEMS - APR 2023; ERECTASTEP CROSSOVER STAIRS - MAR 2023; INFORMATION ON FIXED LADDER LIFELINES - DEC 2022;(c) Safety net systems. Standalone Bolt Down System – every run is independent . To comply with this standard, therefore, the temporary guardrail stanchion to which one end of the control line is attached must qualify as a guardrail system. hot rolled pickled electric weld tubing, free of sharp edges and snag points. Guardrail systems. Handrails, stair rail systems, and guardrail systems are provided in accordance with §. OSHA 1926. TO: ALL AREA DIRECTORS Paragraph 1926. 1926. A safe and effective way to protect the perimeter of your excavation, our guardrails are easy to install to the wall of your shoring system quickly. 1 m) plus or minus 3 inches (8 cm. Equip scaffolding with toeboards, midrails, and guardrails. Designed to Exceed Global Standards. Swing gate adapters convert a guardrail section to a gate. Cal-OSHA Title 9, 1620. 501(b)(13), including guardrail systems, safety net systems, and personal fall arrest systems, must meet and be used in accordance with applicable requirements in 1926. Though the terms guardrails and handrails are often used interchangeably, they are different structures both in use and requirements. Our KATTGUARD roof guardrail systems provide continuous fall protection to keep safety a priority while working on a roof. OSHA Instruction STD 3-10. The strict requirements of OSHA, Canada, New York City and even California are inside the design capabilities of this roof railing system. 500-1926. KeeGuard Rooftop Guardrail is the most common. ANSI/ASSE A1264. Safety yellow SafePro roof guardrails are available in 6’, 8’, and 10’ sections. 501(b)(1) by raising the top rails on the pictured catch platform to a height 39-45 inches above the walking/working surface of. 6 feet (1. Excep-tion: When the employer can dem-The prefab industrial handrail system ships quickly, and is long lasting, easy to install, and OSHA compliant. 501(b)(10) and 1926. Modular Safety Rail Systems. 24) that consists of upright members which have connection points for. 1 m) plus or minus 3 inches (8 cm) above the walking/working level. Both single and double railing systems are a standard guardrail installation option. This guide from the National Safety Council provides an overview of guardrail systems, their components, installation, inspection and maintenance. Sets forth safety requirements for areas where danger exists of persons or objects falling through floor or wall openings,. 502 of this subpart. Fall protection is required for employees when working 10' or more above the next lower level. OSHA compliant – under continuous self-test . Under these provisions,. 1926. Self-rescue devices used to self-rescue after a fall must meet the following requirements: (i) Use self-rescue devices. 501(b)(12) states an explicit preference for use of conventional fall protection (fall restraint or fall arrest, safety nets, or guardrails) instead of alternative fall protection measures such as a CAZ or safety monitoring system. ing by the use of guardrail systems, safety net systems, or personal fall ar-rest systems. When midrails are used, they must be installed at a height approximately midway between the top edge of the guardrail system and the platform surface. 152 (f) (2) Leakage or spillage of flammable liquids shall be disposed of promptly and safely. §1926. 8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. 29(b)(3) Guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2. 501(b)(12), and 1926. Do the spaces between the studs or the floor holes of the chase require fall protection (such as a guardrail system or cover) under §1926. According to OSHA – Guardrail systems must be capable of withstanding at least 200 pounds of force applied within 2 inches of the top edge, in any direction and at any point along the edge, and without causing the top edge of the guardrail to deflect downward to a height less than 39 inches above the walking/working level. In this article, you’ll learn about the three types of OSHA-certified roof guardrails. [55 FR 47687, Nov. Load Requirement: It should be to hold a load from a 200-pound weight that is. 152 (f) (3) Category 1, 2, or 3 flammable liquids may be used only. The Ballasted Guardrail System is a versatile and effective passive fall protection system that can be used at perimeters, open curbs, skylights, stair openings, and in other areas where the leading edge requires fall protection. 5” H. 14, 1990; 56 FR 47689, Jan. Further, OSHA standard 1910. Railings: 1-5/8 inch (41 mm) O. 502 (b) (1) Top edge height of top rails, or equivalent guardrail system. The 360 Hide-A-Rail Collapsible Guardrail System is a completely non-penetrating Safety Rail system that has been independently certified and tested to meet all OSHA Fall Protection regulations and standards for guardrail, sections 1910. 28; 1910. 0 ˜ . Except as provided in 1926. OSHA requirements for standard stairs. 29 (b) (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the. It is made of powder-coated steel and is available in a variety of colors to match your building's surroundings. These systems are offered in selections, such as non-penetrating, fixed and portable, to fit your passive fall protection system. However, if the guardrail system is less than adequate, or the worker leaves the safety of the work platform, an additional fall protection. 814-623-8125 . Connect rails and posts with included slip-on fittings to quickly assemble a railing. The employer must ensure each. Unable to fetch comments. 453, A guardrail is, first and foremost, a safety barrier intended to shield a motorist who has left the roadway. Determine which protection system to use for a given fall hazard. 1(1). To elaborate, the free-standing nature of this guardrail. The toprail of a guardrail system commonly is constructed to 42” from the walking/working surface, but some vary between 39” and 45”. Bounce-Back Guardrails. On November 18, 2016, OSHA published a final rule on Walking-Working Surfaces and Personal Protective Equipment (Fall Protection Systems) in the Federal Register ( 81 FR 82494 ). These regulations were issued by the U. A detent pin on each pivot assembly locks the safety guard rail in the upright position. Standard rivet nut railing attachment system. To meet OSHA requirements in the construction industry, if workers are six feet or more above a lower level, there must be protection from falling by the use of. The use of wire ropes as top rails and intermediate rails of guardrail systems used for perimeter protection or for guardrails used on scaffolding meeting the equivalent requirements of 29 CFR 1926. 6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems,. Compliant fall protection (guardrail system) 2. ( 13) Work on low-slope roofs. 6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. 1926. ( ii) Each employee using a rope descent system 4 feet (1. Our portable guard railing is 42 inches tall. (1) United Rentals carries a wide variety of safety guardrails for rent. This is only partially the case. You also requested clarification on when employees must tie-off when a guardrail system is removed to facilitate hoisting. Babcock-Davis' OSHA compliant Weighted Base Guardrail is a portable railing system that is designed to keep people safe while working on the rooftops and other structures. 8m) or more in depth shall be protected from falling by guardrail systems, fences, barricades, or covers. Guardrail systems can be used on many work surfaces, including rooftops, platforms, mezzanines,. 502 (b) For more than 35 years, RailGuard 200 rails and bases have been protecting the leading edge on rooftops. 6 m) from the roof edge, the employer must ensure each employee is protected from falling. ,. 761 (c) (1) (ii) The proper procedures and equipment to perform multiple lifts required by § 1926. The following incidents have been investigated by the Office of Engineering Services in OSHA’s Directorate of Construction. The employer must ensure:This guardrail system would be an ideal use for manhole barricades, mezzanines, rail car platforms, ramps, construction sites, assembly and break areas and crowd control. Fall Protection on scaffolds OSHA scaffolding standards are at volume 29 of the Code of Federal Regulations (CFR) sections 1926. Guardrail systems must be capable of withstanding at least 200 pounds of force applied within 2 inches of the top edge, in any direction and at any point along the edge, and without causing the top edge of the guardrail to deflect downward to a height less than 39 inches above the walking/working level. 8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. ( 2 ) Fall arrest system components shall be used in fall restraint systems and shall conform to the criteria in § 1926. 501(b)(1), even where there is a permanent guardrail with a 36-inch top rail that, pursuant to STD 01-01-010, is acceptable for. Product Features. Where a mason performs overhand bricklaying and related work 6 feet above lower levels, the requirements for fall protection systems can be satisfied by the use of guardrail systems, safety net systems, personal fall arrest systems, or by creating a controlled access zone in which the mason works. In regards specifically to roof fall protection, the 1910 standard specifies for low-slope roofs that when “work is performed less than 6 feet (1. Each employee at the edge of an excavation 6 feet deep, or deeper, must be protected from falling by guardrail systems, fences, or barricades. 502(b) relates to guardrail systems. Available in multiple lengths and heights, Ideal’s steel guardrail is sleeved in a durable HDPE plastic and available in both one line and. The end treatment tests are then conducted by having a vehicle strike the rail dead-on and also at an angle. The following is an excerpt from OSHA 1910. Safety Boot Guardrail System ® Safety Boot ® Tall Guardrail Brace Provides Guardrail Protection Up To 65 Inches P. CAL/OSHA COMPLIANCE: This guardrail system if installed in the state of California or Washington, requires a maximum spacing between uprights/stanchions of 8 feet on center (96 inches or 2. Requirements for work performed on scaffolds, ladders, and aerial lifts are in Part 1926 – Subpart L, Subpart X, and 1926. 23 & 1926. American National Standards Institute (ANSI) ANSI/ASSE A1264. General OSHA compliant guardrail systems for car tops, open hoistways or escalator wellways shall have a top rail 42 in. That original yellow railing represents over 35 years of industry experience, quality, and rigorous testing. The EDGE 360 mobile safety railing is completely non-penetrating roof guardrail system and has been independently certified and tested to meet all OSHA Fall Protection regulations and standards for guardrail, sections 1910. The GuardRail protective railing system comes in two styles: Single or Double Rail. ”. 502(k)] and their use shall comply with the following provisions:The section of the OSHA code that specifies most of the primary guardrail and handrails as it directly relates to safety railing is 1910. 28; 1910. ( ii) Each employee using a rope descent system 4 feet (1. EHS Intelligence Environment Health Safety Leadership Standards Construction PPE Safety Technology Training & Engagement Emergency Management COVID-19 Crisis Industrial Hygiene. 1, Safety Requirements for Workplace Walking/Working Surfaces and Their Access; Workplace Floor, Wall and Roof Openings; Stairs and Guardrail Systems. Protection between top rail and floor, platform, runway, or stair treads, equivalent at least to that afforded by a standard intermediate rail (§1910. Toprails and midrails of guardrail systems must be at least one-quarter inch (0. (vi)] of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph [1926. This can be deployed around shipping pits, mezzanine perimeters, or a1926. -. The OSHA requirements state that guardrails should be able to resist at least 200 pounds of pressure applied directly to the structure. OSHA Instruction STD 3-10. 28(b)(1)(i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1. Full-service FRP Solutions. 6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems. Anchorage. Mast Climbing Scaffold Engineering Investigations and Analyses. Collapsible guardrail enables rooftops to maintain desirable sightlines. 500, Guardrails, handrails & guards. When the employer can demonstrate that it is not feasible or creates a greater hazard to use guardrail, safety net, or personal fall protection systems on residential roofs, the employer must develop and implement a fall protection plan that meets the requirements of 29 CFR 1926. All GuardRail columns are powder coat painted safety yellow. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (877) 723-3766. SUBJECT: 1926. O. Toggle navigation. The employer must ensure guardrail systems meet the following requirements: 1910. Unless stated otherwise, the employer must ensure that all fall protection and falling object protection required by this section meet the criteria in § 1910. 502 - Infeasibility of 6 foot free fall limit. Resources. Ideal for contractors during construction, this guardrail eliminates the need for tie-off points and expensive safety equipment. Guardrail systems that are not at least 42 inches high can be cited as a technical. e. Last updated: Tuesday,. warning line systems. , offers safety training, program implementation and management tailored to companies of all sizes. The employer must ensure guardrail systems meet the following requirements: (1) The top edge height of top rails, or equivalent guardrail system mem-bers, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walk-ing-working surface. 593. The GuardRail protective railing system comes in two styles: Single or Double Rail. sales@fixfastusa. Slope between 30° and 50° from the horizontal. Any working surface 4 feet or higher must be protected with guardrails on all sides at least 42" tall and have to withstand 200 pounds of force. The roadway may be abutted by steep embankments or side slopes, or it. 23 (a) (1) Used in emergency operations such as firefighting, rescue, and tactical law enforcement operations, or training for these operations; or. Before installing a fall protection system, performing a roof safety audit is crucial. 0 ˜ . 1926. Sections 1926. Personal fall arrest systems. Guardrails need to have a minimum breaking strength of 200 lbs. The United States Department of Labor's Occupational Safety and Health Administration (OSHA) has issued a directive rescinding the Interim Fall Protection Compliance Guidelines for Residential Construction (STD 03-00-001). The only exception is when the employer can. In construction the use of cables or chains to guard door and wall. 502 (see appendix G to this subpart). 453. The Parapet Clamp Guardrail System is a combination base and post for attachment onto structural parapets. LAYOUT & INSTALLATION Railing height to be 42in when installed correctly. Fall protection used to comply with 1926. Rail section made from 1-5/8 inch steel tubing. It is used in combination with 2x4 lumber rails to provide a complete Fall Prevention system. Sincerely, The standard guardrail system features a toprail, intermediate (or mid) rail, and support posts. New build. Height: 42 inches (1067 mm), and 48 inches (1219 mm). (2) The employer shall determine if the walking/working surfaces on which its employees are to work have the strength. OSHA standard 1926. (a) The employer must protect employees from falling into or through holes four feet or more to the ground or lower level by one of the following fall protection systems: (i) A standard guardrail system, or the equivalent, as specified in WAC. 112 section. OSHA is clear on this point. Specifically, the following sections are the most relevant to handrail and stair rail requirements. With an easy ordering process, choose your straight or corner kits, and you will receive all the pipe and fittings for your facility. Utilizing our standard 1¼” Accu-Fit rails – easily trimmed at corners and obstructions to fit your project needs – it features low-profile. Guardrail Systems—1926. OSHA requires the top edge of Guardrail systems to be capable of withstanding a force of at least 200 lbs. Meets and exceeds OSHA standards. In particular, toeboards used for falling object protection are as follows: Toe Board Height Requirements: 29 (k) (1) (ii): “have a vertical minimum height of 3. 23 (b) General requirements for all ladders. Browse Construction Railing Systems. The best case scenario, if a car is careening off the road, would be for that car to come to rest unhindered. Guard Rail for Rent. 451(g)(4)] of. 5”. , guardrail systems, safety net systems, or personal fall arrest systems) unless another provision in 29 CFR 1926. GuardRail 200 Permanent mount family of products can be used for a wide variety of fall prevention applications and so much more. In regards to your specific question, when working from an elevated scissors lift (ANSI A92. 502(b)(1) requires that the top edge height of top rails be 42 inches (plus or minus 3 inches) above the walking/working. 450(b), as well as the requirements of §1926. Product: Permanent Guardrail System. Vertical mounted Permanent Mount bases are anchored to vertical surfaces and use our long leg rail to establish an OSHA-compliant guardrail system. Using safety railing and guardrail systems is one way to help prevent falls and their resulting injuries. 1 m) plus or minus 3 inches (8 cm) above the walking/working level. 1, Safety Requirements for Workplace Walking/Working Surfaces and Their Access; Workplace Floor, Wall and Roof Openings; Stairs and Guardrail Systems. 814-623-8125 . (1) Except as provided by paragraph (a)(3) of this section [below], each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4. 501 (b) (1) through (b) (14), each employee on a walking/working surface 6 feet (1. 112 (c) shall be provided at least every 30’, except as specified in paragraph (e) (2) (iv) of the 1917. 29(b) has an entire section devoted solely to the guardrail system. Home. Stand clear of forklifts in operation. If you need a railing for your worksite, G-rail will get the job done!Roof Guardrail. Grab Bars. Browse Construction Railing Systems. 2 m) or more above a lower level is protected from falling by a personal fall arrest system. com. Karen Hamel, a regulatory compliance specialist and technical writer at New Pig Corp. As for the safety railings and guardrails, you’ll find adjustable and nonadjustable. The scaffolding fall protection requirements are located in 1926. Study with Quizlet and memorize flashcards containing terms like The top rail of a guardrail system must be between _________inches. Guardrail Systems. All of the above. Guardrail Systems (Requirements) The top edge height of top rails, or equivalent guardrail system members, is 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface except: guardrails on scaffolds manufactured after January 1, 2000, are 38 to 45 inches high and guardrails on scaffolds in service before January 1. 29 (b) (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. Crawling boards (chicken ladders) require a PFAS, a guardrail system (with a minimum 200-pound top rail capacity), or a three-fourth inch diameter grabline or equivalent handhold securely fastened beside each crawling. RISERS must be uniform between landings, 30-50 deg, ≤ 9. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11 of this section). The Bodyguard Rail Systems,LLC 1233 Turner Meadow Dr. The employer could potentially have complied with 1926. Other evidence in the record, however, indicates that there are many portable and stand-alone fall protection systems available and in use today in both the rail and truck transportation industries, including overhead cable line systems, moveable stairs with railings, mobile access platforms with railings and/or safety cages and overhead. A ("Directive") 1 generally require[s] conventional fall protection (guardrail systems, personal fall arrest systems, or safety net systems) for work where there is a fall distance of 6. When Does OSHA Require Guardrail? The following is an excerpt from OSHA 1910. POur completely freestanding roof safety railing system goes over the top of the roof hatch and uses compression to fit up against the curb of the hatch. [29 CFR 1926. Guardrail systems must comply with 29 CFR 1926. Lab testing has verified that hand tightening is sufficient to ensure that cross-members will not slip down the vertical tube when contacted with a 200-lb force, as. Definitions. 761 (c) (2) (i) The nature of the hazards associated with connecting; and. OSHA scaffolding standards are at 29 Code of Federal Regulations 1926. ) ( v) Criteria for steps, handholds, ladders, and grabrails/guardrails/railings required by subpart CC are provided in subpart CC. Lifting equipment, such as ladder hoists, swing hoists, or truck-mounted cranes/conveyors, should be used wherever possible. 29, except that personal fall protection systems required by this. 501(b)(13), including guardrail systems, safety net systems, and personal fall arrest systems, must meet and be used in accordance with applicable requirements in 1926. oriented recommendations for the design, . A guardrail consists of a top rail 42” + or – 3” no less than 39”, mid rail at 21” and toe board. NextGen 3000 ™ Universal Guardrail meets the new OSHA Code 1910. With Garlock Safety Systems ®, you have the most trusted name in passive fall protection working for you, and you know it. To prevent employees from being injured from falls, employers must: Guard every floor hole into which a worker can accidentally walk (using a railing and toe-board or a floor hole cover). Powder coated safety yellow. The Safety Boot Guardrail System has been tested and proven to meet OSHA's Fall Protection Regulation (Standard - 29 CFR) 1926. 500-1926. This would include situation number five, above. 451(g)(1) • Guardrail height—The height of the toprail forThe employer must ensure: 1910. For example, there is a system (Ex. 1926. 753 (e). 28 (b) (13) (ii) When work is performed at least 6 feet (1. The other part that’s missed is where cross-braces exist. 1910. com. Need shorter railings? You can cut them shorter too. 8 m) Each employee reaching more than ___________ below the level of the walking/working surface on which they are working, shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. The three basic rail systems are based on the 2006 International Building Code (IBC 1013, “Guards”), the American Association of State Highway and Transportation Offi cials “AASHTO LRFD (Load and Resistance Factor Design) Bridge Design Specifications,” and the Occupational Safety and Health Administration rail system (OSHA, CFR 29, Part. TREADS must support ≥ 1,000 lb, minimum depth ≥ 9. In accordance with 29 CFR § 1910. 28 and 1910. , guardrail systems, safety net systems, or personal fall arrest systems) or alternative fall protection measures allowed under 1926. 451(g)(1) • Guardrail height—The height of the toprail for The employer must ensure: 1910. Any of the above, Every. 501 (b) provides for an alternative fall protection measure. OSHA Standard Number 1910. Duke employees who are not utilizing personal fall protection systems are prohibited from working within 15 feet of an unprotected edge of a roof, without a proper guardrail system, unless the only taskprotection. To learn more about KATTGUARD™ roof guardrail systems, explore the links above. The hazards addressed in this eTool * have been. Particular industries require certain specifications on safety railing systems. 4 km/h), whereas manufacturers of polymer safety guardrail systems rate and test their products at varying impact levels due to variation in guardrail product systems they offer, which can range. True ExplanationGeneral. The fall protection requirements for residential construction are set out in Subpart M at 29 CFR 1926. OSHA standard 1910. Spatz: Thank you for your March 24, 2018, letter we received via email to the Occupational Safety and Health Administration (OSHA) Directorate of Construction regarding applicability of scaffold fall protection requirements. Many guardrail systems adjust and fit stairwells, elevator shafts, open floors, and pits. 5 inches for stands with a top height of 4 feet or more, 36 inches for stands with a top step.